Segments · Devices · Monitoring
Every OT device known, approved and watched
PLCs, HMIs, sensors and cameras cannot run an agent, so they sit on segments of their own behind a Fowlguard Router. Each device reaches nothing until you approve it, every connection follows your rules, and you hear about it when a device goes quiet.
| Device | Vendor | Health | Status |
|---|---|---|---|
| plc-line3-01 | Siemens | Live | Approved |
| hmi-line3 | Rockwell | Live | Approved |
| cam-dock-02 | Axis | Stale | Approved |
| new-device-4 | Unknown | Off | New |
A plant floor that answers to your rules
For devices that cannot run anything of ours, on the networks they already use.
OT Segments on a Port or VLAN
Give each segment a dedicated port, or one VLAN of a trunk. Fowlguard hands out the addresses, the time and the DNS, and holds each device to the address it was given.
A Register of Every Device
Each device listed by name, with the vendor, model, serial number and firmware it announces, its address and when it was last seen.
Access Bound to the Device
A new device reaches nothing, and nothing reaches it, until you approve it. A device that shows up as something else is held. Revoke it and every rule it had is gone.
Report, Then Enforce
Start in Report to see everything Enforce would refuse, then enforce once you know what each device needs.
OT Monitoring
Fowlguard only listens. It never scans or queries a device, and it tells the owner when one goes quiet or announces new firmware.
High Availability
Several Routers can serve one segment, all of them carrying traffic. When one fails, the others take over its devices in seconds, and the devices change nothing.
Rules that name the device, not its address
Every device has a Mesh Hostname. Rules, logs and traces use it, so a device keeps its access when it is renamed, and a new device never inherits an old one's.
- Between people, servers, devices and other segments
- Groups by name pattern, such as plc-line3-*
- Every connection allowed or refused in the log
| Source | Target | Service | Status |
|---|---|---|---|
| plc-line3-* | historian | TCP 4840 | Carried |
| Line 3 Engineers | hmi-line3 | TCP 5900 | Carried |
| cam-dock-* | nvr-01 | TCP 554 | Waiting |
The internet on your terms, for devices too
OT devices are part of Everyone. Your Access Policy and firewall rules apply to them, rules written for OT devices come first, and other internet services stay closed until a rule opens them.
- Sites, categories and ports, judged for every device
- TLS Inspection keeps OT devices out of decryption
- Only approved devices reach anything at all
| Time | Source | Destination | Result |
|---|---|---|---|
| 09:41 | hmi-line3 | updates.example.com | Allow |
| 09:40 | cam-dock-02 | 198.51.100.20:23 | Block |
| 09:38 | plc-line3-01 | files.example.net | Block |
OT Security works with the rest
Static-address devices on a dedicated port, and a gateway on your existing LAN, come with Internet Access. Rules between segments come with Private Access.
OT Security is $2 per OT device per month, on Essentials, Advanced or Enterprise. The Router software is free.
Asked often
Does Fowlguard scan my devices?
No. Nothing is ever sent to a device to monitor it. Fowlguard notices what each device does and announces on its own.
Do the devices need anything installed?
No. They connect to a segment served by a Fowlguard Router and keep working as they are.
Who decides what a device may reach?
Your administrators. They approve each device and write the rules. Fowlguard never opens access on its own, and a suggested rule takes effect only when someone accepts it.
What about traffic between devices on one segment?
It stays on your switch and no rule applies to it. Put devices that should be kept apart on separate segments.
How is it billed?
Per OT device, per month, at $2, counting each device that was on one of your OT segments that month.